GB 20044-2012 Translated English of Chinese Standard. GB20044-2012: Electrical Accessories - Portable Residual Current Devices without Integral Overcurrent Protection for Household and Similar Use (PRCD)https://www.chinesestandard.net, 13/03/2018 - 108 páginas This standard specifies the classification, characteristics, marking and product information, standard conditions for operation and installation in service and for installation, requirements for construction and operation and tests of portable devices for household and similar uses. This standard applies to PRCDs, consisting of a plug, a residual current device (RCD) and one or more socket-outlets or a provision for connection, functionally independent of, or functionally dependent on, line voltage. They do not incorporate overcurrent protection. They are intended for single-phase circuits for rated currents not exceeding 16A for rated voltages not exceeding 250V a.c. They are intended to provide protection against shock hazard in case of direct contact, in addition to the protection provided by the fixed installations for the circuit downstream. |
Índice
Example for Test Circuit for Verification of Ageing of Electronic Components | 8 |
Marking and Other Product Information | 15 |
Minimum Crosssectional Area of Flexible Cable Suitable for Nonrewirable Plugs | 23 |
Conductor Makeup | 36 |
Tests of Resistance to Mechanical Vibration and Impact | 51 |
Makeup of Cables Suitable for the Retention Test of Rewirable PRCDs | 64 |
Examples of Types of Connection Classified According to 4 1 | 70 |
Test Circuit for the Verification of the Correct Operation of PRCDs in the Case | 76 |
Arrangement and Dimensions of the Electrodes for the Tracking Test | 82 |
Table A 1 Test Sequences | 92 |
Palavras e frases frequentes
a.c. component alternating current applied auxiliary switch breaking capacity checked by inspection clamping clearances and creepage closed position Compliance is checked comply conditional short-circuit current connected correct operation creepage distances current protection plug current-carrying dependent on line disruptive discharge earthing circuit earthing terminal Electromagnetic Compatibility fault current flexible cable GB/T impulse voltage influencing quantity insulating material line voltage measured Non-rewirable PRCDs normal Note operating means overcurrent plug and socket-outlet pole polyvinyl chloride portable socket-outlet PRCD shall trip PRCD under test PRCDs classified according PRCDs functionally dependent Preferred Values prospective current pulsating direct current rated conditional short-circuit rated current rated voltage re-close requirements Residual Current Devices residual current protection residual operating current residual short-circuit current Resistance resistor rewirable PRCDs SCPD screw thread specified conditions specified in Table supply switch S1 temperature rise test circuit test conditions test current test device test is carried test sequences thermoplastic torque Verification wire